Designed to bring simplicity to pH testing, the HI991003 pH/ORP Meter is designed specifically for use in manufacturing and environmental testing protocols. The specialized probe features a titanium body, integrated temperature sensor, and cloth junction.
- ±0.02 pH accuracy; ±1 mV ORP accuracy
- Comes with all the necessary solutions and batteries- everything you need to get started measuring right away.
- Specialized for direct pH and ORP measurement.
Probe Condition
An on-screen indicator provides visual confirmation that your probe is working at its best.
Low Battery Indicator
The included batteries provide 1400 hours of continuous use. When the battery level is below 10%, a warning symbol will blink to indicate low battery condition. When low battery power may affect your results, the meter will shut down to avoid erroneous readings caused by low battery level.
Automatic Shut-off
The auto-off feature can be set to shut the meter off at 8 or 60 minutes, or it can be disabled so that the meter continuously stays on. The auto-off feature prolongs battery life for peace-of-mind and energy savings if the meter is accidentally left on.
Built to be Durable
Designed to withstand the knocks, drops, and spills of real life, the new IP67 body ensures top performance in any environment. These meters are protected against dust and water intrusion from any direction.
Portable Design
Made to fit comfortably in your hand for on-the-go testing, the multilevel LCD display provides at-a-glance readings of pH, ORP, and temperature from any angle and dual button operation streamlines the testing process for any user.
Quick Connect Probe
A Quick Connect DIN connector makes attaching and removing the probe simple and easy. The rubber coating protects the cable and provides a water-tight seal without twisting.
Your measurements require detailed attention; so should your electrode. The HI991003 Portable pH/ORP Meter features a replaceable HI12973 probe that has been carefully designed specifically for pH and ORP measurements encountered in a variety of manufacturing and environmental testing protocols.
Titanium Body
The titanium body protects your pH electrode from accidental breakage, making it ideal for measurements in plating baths. It also serves as a matching pin to reduce problems caused by electrical currents.
Platinum ORP Sensor
Provides the best response over a wide range of applications.
Cloth Junction
When readings appear sluggish, simply pull out some of the cloth material from out from its position t renew the junction with an uncontaminated, fresh surface.
Specification Name | Detail |
---|---|
sku | HI991003 |
pH Range | -2.00 to 16.00 pH / -2.0 to 16.0 pH |
pH Resolution | 0.01 pH / 0.1 pH |
pH Accuracy @ 25°C / 77°F | ±0.02 pH / ±0.1 pH |
pH Calibration | Automatic, 1 or 2 point selectable buffer set Standard: 4.01; 7.01; 10.01 or NIST: 4.01; 6.86; 9.21 |
mV Range | ±825 mV (pH-mV) |
mV Resolution | 4 mV |
mV Accuracy | ±1 mV (pH-mV) |
Temperature Range | -5.0 to 105.0 °C/23.0 to 221.0 °F |
Temperature Resolution | 0.1 °C/0.1 °F |
Temperature Accuracy @ 25°C / 77°F | ±0.5 °C up to 60 °C; ±1.0 °C outside ±1.0 °F up to 140 °F; ±2.0 °F outside |
Temperature Compensation | Automatic -5.0 to 105.0 °C/23.0 to 221.0 °F |
Power Supply | 1.5V AAA batteries (3 pcs.) |
Power Consumption | approx. 1400 hours of continuous use |
Environment | 0 to 50°C (32 to 122°F); RH max 100% RH max. 100% |
Dimensions | s 154 x 63 x 30 mm (6.1 x 2.5 x 1.2”) |
Weight | 199 g (6.91 oz.) with batteries |