Hanna HI6000-3 EC/TDS Module

Our EC/TDS module (HI6000-3) is compatible with our Multiparameter Modular System.

  • Your choice of measurement Unit: Conductivity – μS/cm, mS/cm, Resistivity – Ω•cm, kΩ•cm, MΩ•cm, TDS – ppm, ppt, and Salinity – (ppt, PSU, %)
  • Automated Guidance and Verification that provides step-by-step instructions and automatically ensures USP limits for temperature, conductivity, and stability, ensuring accurate results

 

Specification Name Detail
Sku HI6000-3
Conductivity Range 0.000 to 9.999 μS/cm; 10.00 to 99.99 μS/cm; 100.0 to 999.9 μS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm
Conductivity Resolution 0.001 μS/cm; 0.01 μS/cm; 0.1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm
Conductivity Accuracy ±1 % of reading or ±0.010 μS/cm, whichever is greater
Conductivity Cell Constant 0.0500 to 200.0000 /cm
Conductivity Calibration Type Automatic; Manual
Conductivity Calibration Points Single Up to 5
Conductivity Calibration Solutions 84 μS/cm; 1413 μS/cm; 5000 μS/cm; 12880 μS/cm; 80000 μS/cm; 111800 μS/cm
Resistivity Range 1.0 to 99.9 Ω•cm; 100 to 999 Ω•cm; 1.00 to 9.99 KΩ•cm; 10.0 to 99.9 KΩ•cm; 100 to 999 KΩ•cm; 1.00 to 9.99 MΩ•cm; 10.0 to 100.0 MΩ•cm
Resistivity Resolution 0.1 Ω•cm; 1 Ω•cm; 0.01 KΩ•cm; 0.1 KΩ•cm; 1 KΩ•cm; 0.01 MΩ•cm; 0.1 MΩ•cm
Resistivity Accuracy ±1 % of reading or ±1 Ω•cm, whichever is greater
Total Dissolved Solids (TDS) Range 0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt; actual TDS (with 1.00 factor)
Total Dissolved Solids (TDS) Resolution 0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt
Total Dissolved Solids (TDS) Accuracy ±1 % of reading or ±0.01 ppm, whichever is greater
Salinity Range 0.00 to 42.00 PSU (Practical Salinity Scale); 0.00 to 80.00 ppt (Natural Sea Water); 0.0 to 400.0 % (Percent Scale)
Salinity Resolution 0.01 PSU; 0.01 ppt; 0.1 %
Salinity Accuracy ±1 % of reading
Salinity Calibration 1 point, using 100 % salinity calibration solution (% scale only)
Temperature Range -20.0 to 120.0 °C; -4.0 to 248.0 °F; 253.2 to 393.2 K
Temperature Resolution 0.1 °C; 0.1 °F; 0.1K
Temperature Accuracy ±0.2 °C; ±0.4 °F; ±0.2 K
Temperature Calibration Single point, adjustable
Reference Temperature 5.0 to 30.0 °C (41.0 to 86.0 °F , 278.2 to 303.2 K)
Temperature Coefficient 0.00 to 10.00 %/°C
Reading Mode Direct; Direct/Autohold; Direct/USP (Conductivity only)
Basic View Measurement data; Measurement profile (if enabled); Stability status
Simple GLP View Basic view information; Last calibration date and offset
Full GLP View Simple GLP information; Calibration point details (conductivity and salinity)
Graph View Basic view information; Measurement versus time graph
Table View Basic view information; table with measurements updated every second