Our EC/TDS module (HI6000-3) is compatible with our Multiparameter Modular System.
- Your choice of measurement Unit: Conductivity – μS/cm, mS/cm, Resistivity – Ω•cm, kΩ•cm, MΩ•cm, TDS – ppm, ppt, and Salinity – (ppt, PSU, %)
- Automated Guidance and Verification that provides step-by-step instructions and automatically ensures USP limits for temperature, conductivity, and stability, ensuring accurate results
Specification Name | Detail |
---|---|
Sku | HI6000-3 |
Conductivity Range | 0.000 to 9.999 μS/cm; 10.00 to 99.99 μS/cm; 100.0 to 999.9 μS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm |
Conductivity Resolution | 0.001 μS/cm; 0.01 μS/cm; 0.1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm |
Conductivity Accuracy | ±1 % of reading or ±0.010 μS/cm, whichever is greater |
Conductivity Cell Constant | 0.0500 to 200.0000 /cm |
Conductivity Calibration Type | Automatic; Manual |
Conductivity Calibration Points | Single Up to 5 |
Conductivity Calibration Solutions | 84 μS/cm; 1413 μS/cm; 5000 μS/cm; 12880 μS/cm; 80000 μS/cm; 111800 μS/cm |
Resistivity Range | 1.0 to 99.9 Ω•cm; 100 to 999 Ω•cm; 1.00 to 9.99 KΩ•cm; 10.0 to 99.9 KΩ•cm; 100 to 999 KΩ•cm; 1.00 to 9.99 MΩ•cm; 10.0 to 100.0 MΩ•cm |
Resistivity Resolution | 0.1 Ω•cm; 1 Ω•cm; 0.01 KΩ•cm; 0.1 KΩ•cm; 1 KΩ•cm; 0.01 MΩ•cm; 0.1 MΩ•cm |
Resistivity Accuracy | ±1 % of reading or ±1 Ω•cm, whichever is greater |
Total Dissolved Solids (TDS) Range | 0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt; actual TDS (with 1.00 factor) |
Total Dissolved Solids (TDS) Resolution | 0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt |
Total Dissolved Solids (TDS) Accuracy | ±1 % of reading or ±0.01 ppm, whichever is greater |
Salinity Range | 0.00 to 42.00 PSU (Practical Salinity Scale); 0.00 to 80.00 ppt (Natural Sea Water); 0.0 to 400.0 % (Percent Scale) |
Salinity Resolution | 0.01 PSU; 0.01 ppt; 0.1 % |
Salinity Accuracy | ±1 % of reading |
Salinity Calibration | 1 point, using 100 % salinity calibration solution (% scale only) |
Temperature Range | -20.0 to 120.0 °C; -4.0 to 248.0 °F; 253.2 to 393.2 K |
Temperature Resolution | 0.1 °C; 0.1 °F; 0.1K |
Temperature Accuracy | ±0.2 °C; ±0.4 °F; ±0.2 K |
Temperature Calibration | Single point, adjustable |
Reference Temperature | 5.0 to 30.0 °C (41.0 to 86.0 °F , 278.2 to 303.2 K) |
Temperature Coefficient | 0.00 to 10.00 %/°C |
Reading Mode | Direct; Direct/Autohold; Direct/USP (Conductivity only) |
Basic View | Measurement data; Measurement profile (if enabled); Stability status |
Simple GLP View | Basic view information; Last calibration date and offset |
Full GLP View | Simple GLP information; Calibration point details (conductivity and salinity) |
Graph View | Basic view information; Measurement versus time graph |
Table View | Basic view information; table with measurements updated every second |